Building Owner Compliance Calendar 2027 Singapore: Inspections and Deadlines
A Singapore building owner's 2027 calendar is built from a few dated changes and a long list of repeating inspections: daily and monthly water and maintenance checks, six-monthly checks, yearly lift, fire, electrical, gas and water tank checks, and multi-year structural and facade inspections. This guide lists each item by month or interval, who it applies to, the rule, and where to read more.
Written in November 2026 from published rules; check the linked official sources for updates.
The wider map is in the Singapore Building Compliance Handbook 2027. Dates for notice-driven inspections are set by the agency, not by this calendar, so the monthly slots below mark when a rule has a published date and suggest diary slots where it does not.
Dated items in 2027
January 2027, dormitory standards. Who: dormitory operators. Rule: MOM's two interim relaxations of the New Dormitory Standards begin on 1 January 2027, with one running to 31 January 2030. Approvals from the technical agencies and MOM are needed before adopting either. See dormitory standards.
January 2027, manpower. Who: contractors and employers. Rule: higher Employment Pass and S Pass minimum salaries for new applications from 1 January 2027. See the 2027 PE endorsement guide.
March 2027, railway protection. Who: anyone building near MRT lines in compressible soils. Rule: the header date of LTA's circular is 1 March 2027, while its text says 1 September 2026. Treat it as live. See building near MRT lines.
By 31 May 2027, Fire Certificate form (example). Who: owners of designated buildings. Rule: SCDF's worked example is a certificate ending 31 May 2026, renewed into a 3-year certificate, with annual forms due by 31 May 2027 and 31 May 2028. Check your own certificate's dates. See Fire Certificate inspections.
June 2027, maximum maintenance charge. Who: developers of new strata projects. Rule: approval is needed before selling units where planning permission is applied for on or after 1 June 2027.
Through 2027, Periodic Facade Inspection. Who: buildings over 13 m and over 20 years old. Rule: first-cycle inspections continue, by our arithmetic to the end of 2028. See Periodic Facade Inspection.
Through 2027, shophouse usage declaration. Who: shophouse owners with a PSI due. Rule: a 12-month BCA and URA pilot that began on 8 May 2026 requires engineers to declare observed use. See Periodic Structural Inspection.
Monthly and quarterly checks
Every month, lifts and escalators. Who: owners of lifts and escalators. Rule: escalators monthly; most lifts at the manufacturer's frequency or at least monthly, by a BCA-registered service contractor. See lift and escalator inspections.
Every month, cooling towers and pools. Who: cooling tower owners and licensed pool operators. Rule: monthly plate count tests for cooling towers and monthly laboratory water tests for pools, per NEA.
Every quarter, Legionella tests. Who: owners of cooling towers, spa pools and pools with aerosol features. Rule: quarterly Legionella counts, with cooling tower results submitted to NEA. See building inspection in Singapore.
Six-monthly checks
Suggested diary slots: January and July. Windows and air-conditioner supports. Who: every homeowner and building owner. Rule: BCA advises checking all windows and air-conditioner supports at least every 6 months; casement windows need stainless steel rivets fitted by an approved window contractor. See window safety.
Communal electrical services. Who: multi-tenanted buildings and condominiums. Rule: EMA's handbook sets inspection by the Licensed Electrical Worker at least once in 6 months for communal services.
Yearly checks
Lift and escalator Permit to Operate. Who: lift and escalator owners. Rule: a 12-month permit, renewed after an annual examination, inspection and test supervised by a Specialist Professional Engineer. Testing must start within 3 months before expiry. Operating without a valid permit carries a fine of up to $20,000, imprisonment of up to 12 months, or both.
Fire systems inspection. Who: designated buildings. Rule: a Professional Engineer inspects the fire protection systems every year, even though the Fire Certificate is valid for 36 months from 1 April 2026. Missing the annual form in a non-renewal year leads to revocation under SCDF's circular.
Water storage tanks. Who: any water service installation with a tank, except landed residential property. Rule: at least once every 12 months, a Licensed Plumber inspects, cleans where necessary and certifies; late certification is an offence with a fine of up to $10,000, imprisonment of up to 12 months, or both.
Electrical and gas installations. Who: licensed electrical installations and non-residential gas premises. Rule: at least once a year by the Licensed Electrical Worker, and gas pipework in non-residential premises annually by a licensed gas service worker or PE.
Pressure vessels and lifting equipment. Who: workplaces. Rule: steam boilers yearly and air receivers every 2 years by an Authorised Examiner; MOM no longer sends reminders. See PE endorsement for lifting operations.
Multi-year inspections, triggered by a BCA notice
Every 3 years, Fire Certificate renewal. Rule: apply at least 2 months before the certificate expires.
Every 5 years, Periodic Structural Inspection for non-residential buildings; every 10 years for buildings with at least 90% residential floor area. Who: all buildings except landed houses used solely as residences and temporary buildings. See PSI versus PFI.
Every 7 years, Periodic Facade Inspection. Rule: appoint a Competent Person within 2 months of the notice; failure carries a fine of up to $20,000.
What has not changed
The intervals above are the same as in 2025 for structure, facade, lifts and water tanks.
Landed houses used solely as residences remain outside PSI and PFI, so owners schedule their own checks.
Owners still carry the duty to keep exterior features securely fixed, with a fine of up to $10,000, imprisonment of up to 12 months, or both.
Common mistakes
Waiting for a reminder. PUB tells owners not to, and MOM no longer sends them for pressure vessels.
Assuming the 3-year Fire Certificate removed the yearly inspection.
Treating PSI and PFI as one job. They need separate reports.
Losing records. Lift records must be kept for at least 5 years.
Leaving unauthorised works for the inspector. See unauthorised mezzanines.
FAQ
Which inspections must a condominium plan for in 2027?
Monthly lift maintenance, yearly lift, fire and water tank checks, six-monthly communal electrical inspections, plus PSI every 10 years and PFI every 7 years once eligible.
How do I know when my PSI or PFI is due?
BCA serves a notice. For PFI BCA has said it issues advisories about a year before. Check the date on your notice.
Do landed homeowners have any yearly duty?
Window checks every 6 months are advised, and owners must keep exterior features, slopes and retaining walls maintained. See retaining walls and slopes.
Is the Fire Certificate still yearly?
The certificate is renewed every 36 months, but the annual PE inspection and form remain.
Who certifies lifts?
A Specialist Professional Engineer in lift and escalator engineering; a civil or structural PE cannot sign. See how to check a Professional Engineer.
Sources
CVC Engineers is a multidisciplinary practice that takes architectural, civil, structural and geotechnical scope under one appointment, including periodic structural inspections and building inspection services. WhatsApp +65 9342 7551. Last reviewed: November 2026.