Window Safety and Retrofitting in Singapore: Owner Duties and Inspections
In Singapore the homeowner, not the town council or the condominium management, is responsible for keeping the windows of a flat safe. Since 2004, BCA has required owners to replace all aluminium rivets in casement windows with stainless steel rivets, and any installation, repair or retrofitting must be done by an approved window contractor. If a window falls because it was not maintained, the owner can be fined up to $10,000, jailed for up to one year, or both.
This article explains the retrofitting rule, the "check, clean, change" routine, who may work on windows, and how windows fit into the wider inspection regimes. It belongs to our complete guide to building inspection in Singapore.
What is the 2004 window retrofitting requirement?
Since 2004, a BCA retrofitting order has required homeowners to replace all aluminium rivets in casement windows with stainless steel rivets. Aluminium rivets were the traditional fixing, but aluminium corrodes, and BCA's investigations found corroded rivets to be the main cause of fallen casement windows. BCA's Strata Management Guide 12 describes it as a law passed in 2004 to mandate the replacement of all aluminium rivets with stainless steel rivets in residential properties, and states that where a building obtained its temporary occupation permit before 2004, owners must ensure that all window rivets are changed from aluminium to stainless steel.
BCA's window safety page gives the technical detail:
Replace all aluminium rivets at the variable geometry stays, also called friction stays, which are the hinged arms that hold a casement panel to its frame.
Use type 304 stainless steel rivets complying with BS EN 10088 or equivalent.
The work must be done by an approved window contractor or builder using a trained window installer.
Contractors who come across casement windows that still have aluminium rivets should report them to BCA.
The paperwork differs by property type. BCA's forms are Form A for retrofitting in a private flat, Form B1 for retrofitting in an HDB flat, and Form D for rectification works. The contractor must submit the certificate of completion no later than 14 days after completing the window works.
Who is allowed to install, repair or retrofit windows?
Only an approved window contractor or a licensed builder, working through a trained window installer, may install, repair or retrofit windows. BCA defines these as:
Approved window contractor: a firm registered in BCA's Contractors Registry under workhead RW01.
Builder: a firm registered under general builder workhead GB1 or GB2, which may also install windows.
Trained window installer: an individual certified by BCA, who must have at least 12 months of practical window installation experience and pass the test of the "Safety of Windows" course. The installer must be a director, partner, sole proprietor or employee of the approved contractor or builder.
Window works must comply with SS 212, the specification for aluminium alloy windows, and with the Building Control Regulations. BCA publishes its list of approved window contractors in the BCA Directory, and HDB maintains its own listing for flats. A general handyman or a renovation contractor without the RW01 registration is not permitted to do this work, even for a single rivet change.
What does "check, clean, change" mean?
"Check, clean, change" is the three-step routine BCA and HDB ask homeowners to carry out on their windows at least once every six months.
For casement windows:
Check that fasteners are not rusty or loose.
Clean and oil the joints and moving parts.
Change all aluminium rivets to stainless steel rivets through an approved window contractor.
For sliding windows:
Check that safety stoppers and angle strips are in their proper places.
Clean the tracks and make sure the window panels slide smoothly.
Change worn-out safety stoppers and angle strips through an approved window contractor.
The checking and cleaning are for the owner to do. The changing is for an approved contractor. If you are not confident inspecting your own windows, BCA's advice is to engage an approved window contractor to inspect them.
Why do sliding windows fall?
Sliding windows fall mainly because safety stoppers and angle strips are missing or worn, so the panel lifts out of its track when someone pushes it with too much force. BCA's Strata Management Guide 12 explains what each part does. Safety stoppers reduce the gap between the track and the panel so the panel cannot move vertically. Angle strips form a barrier that guides a lifting panel back into position. Dirty tracks make the problem worse, because a panel that sticks needs more force to move, and that extra force is what dislodges it.
How many windows fall each year?
BCA and HDB recorded 35 fallen windows in the first 11 months of 2023, down from about 50 a year in 2018 to 2020. The joint BCA and HDB media releases give this trend:
2018: 49 cases for the full year.
2019, January to November: 48 cases, of which 24 were casement windows, 19 sliding windows and 5 other types such as louvre windows.
2020, January to November: 49 cases, of which 32 were casement, 16 sliding and 1 louvre.
2021, January to November: 43 cases, of which 22 were casement, 16 sliding and 5 other types. BCA also dealt with 12 poorly maintained windows that were close to dislodging.
2023, January to November: 35 cases, of which 19 were casement, 15 sliding and 1 louvre.
No injuries were reported in the cases covered by the 2019, 2020, 2021 and 2023 releases. In every one of those years casement windows made up half or more of the cases, and the cause BCA gives each time is the same: corroded aluminium rivets that should have been replaced under the 2004 requirement. The 2023 release is the latest BCA release with figures that we were able to open for this review.
What are the penalties for owners?
An owner who fails to replace aluminium rivets in casement windows faces a fine of up to $5,000, a jail term of up to six months, or both. If a window falls because of a lack of maintenance, the owner faces a fine of up to $10,000, imprisonment of up to one year, or both.
These penalties are used. BCA's December 2023 release states that since 2006, 406 individuals have been fined and 94 prosecuted for fallen windows. The corresponding figures were 352 fined and 92 prosecuted as at December 2019, so about 54 more people were fined in the four years between the two releases.
Liability does not depend on anyone being hurt. The offence is the fall caused by lack of maintenance.
Who is responsible in a condominium or an HDB block?
The owner of the flat is responsible for the sliding and casement windows that are part of that flat. BCA's Strata Management Guide 12 divides exterior features in a strata development this way:
Management corporation: fixed, full-length window claddings that are not part of a flat, fixed sun shading devices and vertical greenery.
Subsidiary proprietor: sliding and casement windows that are part of a flat, and the supporting system of an air-conditioning unit.
The exact split depends on the strata title plan. BCA's guidance for condominium owners also lists external openable windows among the features an owner must upkeep. For a management council this matters in two ways. It cannot assume windows are covered by the estate's facade maintenance, and it should remind owners of the six-monthly check. Our article on building maintenance duties of MCSTs sets out the wider division of duties.
Are windows part of the Periodic Facade Inspection?
Yes. Windows are exterior features, and BCA's Guidelines on Periodic Facade Inspection list window defects among the items the Competent Person must look for. The Building Control (Meaning of Exterior Features) Regulations 2021 prescribe "any window, with or without movable parts" as an exterior feature. Section 9.2.6 of BCA's PFI Guidelines, version 1.3 dated September 2026, lists the window defects as:
Dangling window panel
Cracked or missing window glass panels
Rusty or corroded window panel fixings
Failure of screws
The guidelines add that the Competent Person shall report to BCA any dangling windows spotted during the inspection. The Periodic Facade Inspection applies to buildings taller than 13 metres and at least 20 years old, every 7 years. It does not replace the owner's six-monthly check, because a seven-year interval is far too long for a rivet that is already corroding. See which buildings need a periodic facade inspection and what is checked, PSI versus PFI and drones and technology in facade inspection.
There is also a reporting duty. Under the Building Control (Reportable Matters) Regulations 2025, a fallen exterior feature that causes death, injury or damage to other property is a reportable safety incident, to be notified to BCA within 6 hours.
When does window work need a Professional Engineer?
A Professional Engineer is needed when the work involves a safety barrier integrated with a window, unless BCA's standardised designs are used. BCA defines such a barrier as one put in place to prevent falls where there is a vertical drop of 1,000 millimetres or more, and that is integrated with a window. An example is a full-height window where the lower fixed glass panel or a railing is what stops a person from falling.
By default, the homeowner must appoint a Professional Engineer to design the barrier and submit structural plans to BCA when replacing or reinstating it.
If the work follows the Standardised Designs in Annex B of BCA's Approved Document, or is a like-for-like replacement of a railing or balustrade in the same material, design and fixing details, it is treated as insignificant building works, and no engineer, plan approval or permit is needed.
Either way, an approved window contractor or builder with a trained window installer must carry out the work, and the certificate is submitted on Form SB.
Enclosing a balcony, yard or terrace with windows and glass panels in a residential building is itself listed as insignificant building works in the First Schedule of the Building Control Regulations 2003. Our guide to insignificant building works explains where that exemption stops. Where a design falls outside the standardised details, our PE endorsement service covers the barrier design and submission.
Which authority governs what?
BCA regulates window safety under the Building Control Act 1989, and HDB works with BCA on public housing:
BCA: the retrofitting requirement, approval of window contractors and installers, enforcement after a fallen window, the Periodic Facade Inspection.
HDB: its own listing of window contractors for HDB flats, and joint public education and follow-up with BCA on poorly maintained windows.
Management corporations: by-laws on the appearance of windows and grilles, and the exterior features that are common property.
Common mistakes
The recurring errors are simple ones:
Assuming a flat built before 2004 was retrofitted by a previous owner, without looking at the rivets.
Using a handyman or an unregistered contractor for window repairs.
Removing or never replacing the safety stoppers and angle strips on sliding windows.
Forcing a sticking window instead of cleaning the track.
Treating the building's seven-yearly facade inspection as covering the windows of each flat.
Replacing a full-height window or its railing without checking whether it is a safety barrier that needs a Professional Engineer or a standardised design.
FAQ
Are stainless steel rivets compulsory for casement windows?
Yes. Since 2004 owners have been required to replace all aluminium rivets in casement windows with stainless steel rivets.
How often should I check my windows?
At least once every six months, using the check, clean, change steps.
What is the fine if my window falls?
Up to $10,000, up to one year's imprisonment, or both, if the window fell because of a lack of maintenance.
Can I change the rivets myself?
No. Retrofitting must be done by an approved window contractor or builder with a trained window installer.
Who is responsible for windows in a condominium?
The owner of the flat is responsible for the sliding and casement windows that are part of the flat. The management corporation is responsible for fixed claddings and other exterior features that are common property.
Do I need a Professional Engineer to replace a window?
Only if the window includes a safety barrier protecting a drop of 1,000 mm or more and the work does not follow BCA's standardised designs or a like-for-like replacement.
Sources
BCA media release, 12 December 2023: 35 cases of fallen windows in the first 11 months of 2023
BCA Strata Management Guide 12: Management and Maintenance of External Facades and Exterior Features
Building Control (Reportable Matters) Regulations 2025, as published by BCA
Building Control Regulations 2003, First Schedule (Singapore Statutes Online)
CVC Engineers advocates education and public awareness, and has a dedicated team to help resolve this properly. For window safety barriers, facade concerns or a wider building inspection, WhatsApp +65 9342 7551. Last reviewed: November 2026.