Dormitory Transition Scheme: What the 2030 Standards Mean for Factory-Converted Dormitories

Nov 11
3 min read

Updated: Nov 12

Since 1 April 2023 the Foreign Employee Dormitories Act covers every dormitory with 7 or more beds. Existing dormitories that are not on the New Dormitory Standards must now meet interim standards under MOM's Dormitory Transition Scheme (DTS) by 2030, and the New Dormitory Standards by 2040. For a factory-converted dormitory, that means building works inside a structure designed as a factory.

The standards, side by side

  • Residents per room: no maximum before; 12 or fewer under DTS and the New Dormitory Standards.

  • Living space per resident, excluding shared facilities: 3.5 sqm average before; at least 3.6 sqm under DTS; at least 4.2 sqm under the New Dormitory Standards.

  • Toilets: one set per 15 residents before, with common toilets allowed; one set of toilet, shower and hand-wash basin per 6 residents under DTS, en-suite only.

  • Bed spacing: at least 1 m between beds, recommended under DTS and required under the New Dormitory Standards.

Dormitories with government leases expiring in 2033 or earlier are exempt from DTS. If they take a new lease after expiry, the 2030 and 2040 standards apply.

November 2026 update: interim relaxation

On 6 November 2026 MOM announced two interim relaxations of the New Dormitory Standards (NDS), taking effect on 1 January 2027. First, dormitories approved on or after 18 September 2021 and built to the NDS may operate at 3.6 sqm or more of living space per resident and up to 14 residents per room, instead of 4.2 sqm and 12 residents, from 1 January 2027 to 31 January 2030; the 1 m spacing between beds stays mandatory, and the NDS applies again after that period. Second, new short-term dormitories that will cease operations before 2040 (CTQs, TOLQs and QBDs) may be built to the DTS standards instead of the NDS: at least 3.6 sqm per resident and 12 or fewer residents per room, with 1 m bed spacing recommended. Dormitories that intend to operate from 2040 onwards must still be built to the NDS. The relaxations are optional, and operators must first obtain the relevant approvals from the technical agencies and MOM.

MOM licence classes

Class 1 covers 7 to 99 beds, Class 2 covers 100 to 299, Class 3 covers 300 to 999, and Class 4 covers 1,000 beds or more.

Which factories can be converted

JTC considers temporary conversion where the proposal meets planning guidelines and the infrastructure can support it. JTC recognises Ancillary Workers' Dormitories, which house workers of the factory owner or lessee and their sub-contractors, and single employer-operated Secondary Workers' Dormitories. Conversion is not allowed in:

  • High-rise factories with multiple industrial units, such as flatted factories and ramp-up developments

  • Terrace workshops and terrace factories without stand-alone compounds

  • Areas affected by health and safety buffers

  • Areas designated by PUB as red zones

The approval route for a factory-converted dormitory

  1. Apply through the GoBusiness portal for In-Principle No Objection from the agencies. You or your Qualified Person can submit. GoBusiness replaced email applications from 1 October 2026.

  2. Apply for JTC landowner's consent through CORENET. JTC aims to issue consent within 10 working days of receiving documents.

  3. Obtain Temporary Permission from URA, and give JTC a copy within 7 working days of receiving it.

URA's circular of 10 February 2023 raised the allowable quantum for ancillary and secondary uses from 40% to 49% to accommodate temporary workers' dormitories. In the 13 specified industrial areas, Temporary Permission lasts up to three years and is not renewable. A MOM licence is required before the dormitory operates.

What a DTS retrofit means for the building

Dormitory work looks architectural: room layouts, occupancy, toilets and escape routes. It becomes structural as soon as en-suite toilets are added to a factory floor. New wet areas bring slab penetrations for drainage, added dead load from screed, walls and fittings, and falls on floors that were never designed for them. Fewer residents per room also means more rooms and more partitions. The architectural layout and the structural check have to describe the same building.

Grant support

MOM's DTS grant pays per item, with higher amounts in Window 1 (2026 to 2028) than Window 2 (2029 to 2030): $4,200 or $3,000 for a new room meeting the occupancy limit, $9,800 or $7,000 for an en-suite toilet, and $12,300 or $8,800 for an isolation facility. The application period ran from 1 March to 31 August 2026.