PE Endorsement for Demolition and Hacking Works in Singapore: Who Can Sign
Only a Professional Engineer (PE) registered with the Professional Engineers Board (PEB) and holding a valid practising certificate can give a PE endorsement for demolition or hacking works in Singapore, and for structural matters that engineer must be in the civil or structural discipline. A contractor, a hacking specialist or an interior designer cannot sign in the engineer's place, however experienced. Below: who can sign, what the signature certifies, what HDB and condominium management corporations ask for, how to verify the engineer, and what an endorsement for hacking should contain.
Who can sign a PE endorsement for demolition or hacking works?
A PE in the civil or structural discipline with a valid practising certificate. Three official sources say so for three different situations:
Submissions to the Building and Construction Authority (BCA): BCA's structural plan submission page states that only a Qualified Person (QP) who is a registered Professional Engineer in the civil or structural discipline can apply for structural plan approval.
Condominium and strata renovation: BCA's advisory to management corporations of 14 January 2014 says renovation plans involving demolition of non-structural elements, other than floor tiles, should be endorsed by a Professional Engineer in the civil or structural discipline.
HDB flats: HDB's building works guidelines require a Professional Engineer for civil or structural works to supervise the demolition of non-load bearing reinforced concrete elements.
A Qualified Person, as the Workplace Safety and Health (WSH) Council's advisory of 26 March 2025 summarises it, is an architect registered under the Architects Act 1991, or a professional engineer registered under the Professional Engineers Act 1991, who has in force a practising certificate. The broader picture is in our guide to PE endorsement in Singapore.
Why are registration and a practising certificate both needed?
Registration shows the engineer is qualified; the practising certificate is what allows the engineer to practise. PEB's register page states that the practising certificate is renewed on an annual basis and permits a registered professional engineer to engage in professional engineering work within the branch the engineer is qualified to practise.
Two consequences follow for hacking and demolition:
An engineer who is registered but has not renewed the practising certificate for the current year should not be signing.
A PE in the mechanical or electrical branch is not the right signatory for a wall, beam, slab or column. The endorsement must come from a civil or structural PE.
Can a contractor, hacker or interior designer endorse hacking works?
No. None of them is a Qualified Person under the Building Control Act unless separately registered as an architect or a professional engineer with a practising certificate. The roles are different by design:
The contractor carries out the work. Demolition of structural elements needs a builder working under a BCA permit, and BCA's 2014 advisory asks that non-structural demolition in strata buildings be done by contractors whose workers are certified by the BCA Academy.
The interior designer plans the layout and finishes.
The Professional Engineer certifies whether structure is affected and, if it is, designs and supervises the structural work.
There is also a reason of independence. The party that quotes for and carries out the hacking has a commercial interest in the works going ahead, so the system places the structural certification with a registered professional who carries personal responsibility for it. A contractor's method statement, experience letter or "structural-free" declaration is useful information for the engineer, but it is not a PE endorsement, and it does not meet BCA's advisory to management corporations or HDB's guidelines.
For demolition, the WSH Council's alert of 23 June 2023 says the method statement must be prepared by a Professional Engineer; see demolition method statement and demolition plan.
What does the PE actually certify?
It depends on which of three documents is being signed.
Certification that no structural element is affected. The standard wording annexed to BCA's 2014 advisory has the engineer state that he or she has "personally checked the approved structural plan and inspected the structural condition" of the building or unit, and certify that no structural element will be altered or demolished in the proposed renovation works.
Demolition works plans submitted to BCA. The QP certifies plans showing how structural elements are removed safely. For buildings more than 5 storeys high, or more than 40 years old and not landed houses, BCA circular APPBCA-2022-12 adds a declaration that the QP has inspected and appraised the structural elements after soft stripping and that the demolition works shown in the plans are adequate to ensure the works are carried out safely, without impairing the stability of any other part of the building or adjacent property, or affecting public safety.
A demolition method statement. The WSH Council says it must ensure that the stability of the walls, ceilings, slabs, beams and all other structures adjacent to the part being demolished is determined before and during demolition.
In each case the engineer is certifying something specific and checkable, based on the approved plans and a physical inspection.
What is the PE liable for?
A PE who signs carries personal professional and legal responsibility for what was certified. The exposure comes from several directions:
Building Control Act 1989: carrying out building works without approved plans or a permit carries a fine of up to $200,000, imprisonment of up to 2 years, or both. BCA's published enforcement list records a Qualified Person for structural works fined $60,000 in November 2025 for authorising building works without approved plans and making a false declaration, and another fined $40,000 in March 2024 for failing to supervise works in accordance with approved plans.
WSH Act: the WSH Council notes that individuals can be sentenced to a maximum fine of $200,000, imprisonment of up to 2 years, or both, and first-time corporate offenders to a maximum fine of $500,000.
Professional Engineers Act 1991: PEB regulates the conduct of professional engineers under the Professional Engineers (Code of Professional Conduct and Ethics) Rules, and keeps a public list of suspended and recently deregistered engineers.
This is why an engineer will ask for the approved structural plans and visit the unit before signing.
What do HDB and condominium MCSTs require?
HDB requires its own approval before any wall is touched; MCSTs are advised by BCA to require a PE's certification for any demolition other than floor tiles.
HDB flats, under HDB's building works guidelines:
All demolition or alteration of walls can only be carried out after obtaining HDB's approval.
Demolition of non-load bearing reinforced concrete elements, such as partition walls, party walls, stiffeners, lintols or hangers, must be supervised by a PE for civil or structural works, who must also ensure proper repair of any affected reinforced concrete structural elements.
Block, brick, drywall and Ferrolite walls may be demolished only up to the underside of the reinforced concrete beam or slab, and if steel bars are discovered the works stop and HDB is informed immediately.
A PE's endorsement does not override HDB. If HDB treats a wall as structural, it stays.
Condominiums and other strata buildings, under BCA's 2014 advisory to MCSTs:
Demolition involving structural elements needs plans approved by the Commissioner of Building Control, a permit and supervision by a Qualified Person.
Demolition of non-structural elements, other than floor tiles, needs renovation plans endorsed by a civil or structural PE certifying that no structural works are involved, drawn to show existing structures based on the original approved plans.
Whenever structural reinforcement bars are exposed, the works shall be stopped, a PE called in to assess and recommend remedial measures, and BCA notified.
The MCST's power to impose these conditions comes from section 37(4) of the Building Maintenance and Strata Management Act. The residential cases are worked through in PE endorsement for renovation.
How do you verify a PE on the PEB register?
Look the engineer up in PEB's Directory of Professional Engineers with Practising Certificates, which lists engineers with an active practising certificate.
Go to PEB's Find a Professional Engineer page.
Open the Directory of Professional Engineers with Practising Certificates and search for the name on the endorsement.
Confirm the branch of engineering is civil.
If the name is missing, check the List of Suspended and Recently Deregistered PEs, then ask the engineer directly.
If a company is offering the service, check it in the Directory of Licensed Corporations and Partnerships.
The directories and what each one shows are explained in how to check a Professional Engineer in Singapore.
What should an endorsement for hacking contain?
At minimum, what BCA's standard certification contains; in good practice, enough for a third party to see exactly what was checked. Items 1 to 5 below follow BCA's 2014 annex, and items 6 to 8 are good practice.
The engineer's name, and who appointed the engineer: the subsidiary proprietor or the MCST.
The address and unit number.
A statement that the engineer personally checked the approved structural plan.
A statement that the engineer inspected the structural condition of the unit or building.
The certification that no structural element will be altered or demolished, with signature, stamp and date.
A marked-up renovation plan showing existing structural elements against the original approved plans, and each wall or element to be hacked.
The engineer's PE registration number, so that the directory check takes a minute.
Conditions for the work, such as hacking from the top down, stopping if reinforcement is found, and limits on where debris is stacked.
If the works do affect structure, an endorsement letter is the wrong document. The job becomes a QP submission to BCA with plans, calculations and a permit; see types of demolition submission and hacking versus demolition.
When is no PE endorsement needed?
BCA does not require plan approval for insignificant building works in the First Schedule of the Building Control Regulations 2003, which include demolishing or forming an opening in a non-load bearing wall. BCA's 2014 advisory also excludes hacking of floor tiles from its PE certification. HDB, the MCST or a landlord can still ask for an engineer's input, and someone competent has to establish that the wall is in fact non-load bearing: BCA's page on building works not requiring approval advises consulting a Qualified Person when in doubt. The list is in insignificant building works.
Which authority governs what?
PEB, Professional Engineers Act 1991: registration, practising certificates, licensing of firms and professional conduct.
BCA, Building Control Act 1989: who may act as a Qualified Person, plan approval, permits and supervision.
HDB: approval of works in flats and the requirement for PE supervision of certain demolition.
MCSTs, Building Maintenance and Strata Management Act: conditions on renovation in strata lots.
Ministry of Manpower and the WSH Council: safe demolition, including the PE-prepared method statement.
What goes wrong with endorsements?
Problems arise when the endorsement is treated as a formality.
The signatory is not a civil or structural PE, or has no current practising certificate.
The engineer never saw the approved structural plans, or never visited the unit.
The letter certifies "no structural works" for a job that cuts a slab or a reinforced concrete wall.
The owner obtains the endorsement after the hacking is done.
BCA issued its 2014 advisory after cases of unauthorised demolition of structural elements during renovation in strata-titled buildings, some of which led to Dangerous Building Orders being served on the management corporation. The step-by-step sequence for larger jobs is in the demolition process, and the overall framework in our complete guide to demolition in Singapore.
FAQ
Who can sign a PE endorsement for hacking a wall?
A Professional Engineer in the civil or structural discipline who is registered with PEB and holds a valid practising certificate.
Can my renovation contractor or interior designer endorse the hacking?
No. They can prepare drawings and carry out the work, but the certification must come from a PE.
Does a PE endorsement mean BCA has approved the works?
No. The endorsement certifies that no structural element is affected. Works that do affect structure need BCA plan approval and a permit through a Qualified Person.
How do I check the engineer is genuine?
Search PEB's Directory of Professional Engineers with Practising Certificates for the name, and confirm the branch is civil.
Can a PE endorse without visiting the unit?
BCA's standard certification requires the engineer to have personally checked the approved structural plan and inspected the structural condition of the unit.
Sources
CVC Engineers advocates education and public awareness, and has a dedicated team to help resolve this properly, including PE endorsement and demolition plan endorsement. WhatsApp +65 9342 7551. Last reviewed: November 2026.