When Is PE Endorsement Required in Singapore and When Is It Not
PE endorsement is required in Singapore whenever a named rule says a Professional Engineer or Qualified Person must design, certify, supervise or examine the work: structural building works needing BCA plan approval, the scaffolds listed by MOM, tower crane foundations, earth retaining structures deeper than 1.5 m, temporary buildings and large signboards, and periodic structural inspections are the main cases. It is not required by BCA for the insignificant building works in the First Schedule of the Building Control Regulations 2003, although HDB, a management corporation or a landlord may still ask for one.
This page is a decision guide in three lists: required by law, not required by BCA, and not legally required but commonly demanded. Each item names its source. For background, start with the main PE endorsement guide and the plain-language definition of PE endorsement.
When is PE endorsement required in Singapore?
It is required when the Building Control Act, workplace safety and health rules, or an agency's published conditions name a Professional Engineer, a Qualified Person or an Authorised Examiner for the task. BCA's starting rule is broad: a permit is required for all building works except those classified as insignificant building works, and only a Qualified Person who is a registered Professional Engineer in the civil or structural discipline can apply for structural plan approval.
List 1: works where a PE or QP is required by a named rule
Each item below is tied to a published rule.
Structural alterations and other building works needing BCA plan approval. A Qualified Person who is a civil or structural PE applies for structural plan approval, and a permit is obtained jointly with the developer and builder before work starts. For additions and alterations, BCA requires plans endorsed by a PE with a certificate that the building and its foundation can resist the altered forces. Source: BCA structural plan submission page.
HDB demolition of non-structural reinforced concrete elements. HDB requires a PE for civil or structural works to supervise the demolition and ensure proper repair of affected RC structural elements. Source: HDB renovation guidelines for building works.
Scaffolds in the MOM-listed cases. MOM requires a design by a PE for, among others, metal scaffolds exceeding 30 m in height (15 m in a shipyard), scaffolds on cantilever or jib supports, metal scaffolds supporting more than 4 persons in a bay, and outriggers or overhead supports for suspended scaffolds. Source: MOM scaffold contractor FAQ.
Tower crane foundations and wall ties. MOM's tower crane guide states that the foundation and any wall tie shall be designed, and supervised during construction, by a PE of the relevant discipline, who then certifies that they were built to the design. Source: MOM, Use of Tower Crane in Workplace.
Excavations and earth retaining structures deeper than 1.5 m. BCA's June 2026 guidance: up to 1.5 m, plan approval is not required (1 m if the retaining structure is not reinforced concrete or steel); above 1.5 m and up to 4 m, a Qualified Person for structural works; above 4 m, an Accredited Checker as well; above 6 m and classified as geotechnical building works, a QP(Geo) and AC(Geo) in addition. Source: BCA ERSS submission requirements, June 2026.
Temporary buildings under BCA's Permit to Use. The owner must engage a professional civil or structural engineer to design, supervise and inspect the erection, and to apply for the permit. Source: BCA temporary building application page.
Large signboards and banners. A Permit to Use is needed where a sign exceeds 10 sqm and is supported by an advertising structure, or the structure exceeds 10 sqm or its highest point is 4 m or more above the surface it stands on. PE certification is needed for banners exceeding 10 sqm displayed with bars or rods, and banners exceeding 30 sqm. Source: BCA outdoor advertising licence pages.
Lifting equipment and pressure vessels. MOM requires the owner to engage an Authorised Examiner to register lifting equipment, and pressure vessels must be registered by an Authorised Examiner before they are put into operation. An Authorised Examiner for lifting equipment must be a PE holding a practising certificate in the specialised branch of crane, access platform, or lift and escalator engineering. Source: MOM lifting equipment, pressure vessel and Authorised Examiner pages.
Periodic Structural Inspection (PSI). Non-residential buildings are inspected every 5 years and residential buildings every 10 years, by a structural engineer appointed by the owner after BCA's notice. Source: BCA PSI page.
Periodic Facade Inspection (PFI). Buildings taller than 13 m and at least 20 years old are inspected every 7 years by a Competent Person, who is a PE or registered architect holding the facade inspection certificate. Source: BCA PFI FAQ.
Related guides: PE endorsement for scaffolds, lifting operations and crane foundations, hoarding and signboards and the complete guide to mandatory building inspections.
List 2: works where BCA does not require plan approval
BCA does not require plan approval or a permit for the insignificant building works listed in the First Schedule of the Building Control Regulations 2003. The ones owners ask about most, with their limits:
Creating an opening in a non-load bearing wall, or sealing up a wall opening.
Demolition, restoration or reinstatement of any non-load bearing wall.
Enclosing a balcony, yard or terrace with windows and glass panels in a residential building.
A plinth or base not exceeding 2.5 m in height, not on piled foundation, supporting plant or equipment not exceeding 2.5 m in height.
A retaining wall or earth retaining structure not on piled foundation, with a visible height not exceeding 1.5 m in reinforced concrete or structural steel, or 1 m in other materials, and not within 3 m horizontally of another.
Site formation with excavation or filling not exceeding 1,500 mm.
A single-level platform used solely for storage of goods in an industrial building, not accessible to the public, not exceeding 4 m in height and 50 sqm in area, with no beam or slab span over 6 m and no cantilever over 3 m.
A suspended lightweight false ceiling that is not accessible, with a supporting span not exceeding 6 m.
The full list and conditions are in our guide to insignificant building works. Two cautions apply. First, the exemption turns on facts such as whether a wall is load bearing, and that is an engineering judgement. Second, the exemption is from BCA plan approval only. It does not remove the conditions of HDB, a management corporation or a landlord.
Can HDB or the MCST still ask for a PE when BCA does not?
Yes. HDB and management corporations set their own conditions for works in their buildings, and these apply even to works that are insignificant building works under BCA's rules.
HDB. All demolition or alteration of walls can be carried out only after HDB's approval. Existing reinforced concrete structures shall not be tampered with, block or brick walls may be demolished only up to the underside of the RC beam or slab, and work must stop and HDB be informed if steel bars are discovered.
Strata developments. BCA's 2014 advisory tells management corporations that for renovation involving demolition of non-structural elements other than floor tiles, the renovation plans should be endorsed by a PE in the civil or structural discipline certifying that no structural works are involved. The management corporation can impose such conditions under section 37(4) of the Building Maintenance and Strata Management Act.
See PE endorsement for wall hacking in HDB flats and condos and PE endorsement for condo renovation.
List 3: not legally required, but commonly demanded
Many PE endorsements are asked for by contract, not by statute. The requirement comes from a landlord's fit-out manual, a management corporation's by-laws, a main contractor's safety system or an insurer's conditions. Common examples from practice:
A PE's certification that hacking a partition involves no structural element, for a condominium or commercial unit.
A floor loading check before a heavy machine, safe, tank or compactus is placed on an existing slab.
Calculations for racking, storage platforms and equipment supports that fall within the First Schedule limits. See warehouse racking and storage platforms.
Temporary works such as formwork, falsework and working platforms, where the main contractor's procedures call for a PE design.
Which authority governs what?
BCA governs building works; MOM governs scaffolds, lifting equipment and pressure vessels; SCDF governs fire safety works; HDB and management corporations govern works in their own buildings.
BCA, Building Control Act 1989 and Building Control Regulations 2003: plan approval, permits, Qualified Persons, Accredited Checkers, PSI and PFI.
MOM, workplace safety and health law: scaffolds, tower cranes, Authorised Examiners.
SCDF, Fire Safety Act 1993: fire safety plans prepared and submitted by a Qualified Person.
PEB, Professional Engineers Act 1991: who is a Professional Engineer and in which branch.
Common mistakes
Assuming a wall is non-structural without checking the approved structural plans. BCA's 2014 advisory was prompted by cases of unauthorised demolition of structural elements during renovation in strata buildings.
Treating "no BCA approval needed" as "no approval needed". HDB approval, management consent and SCDF requirements are separate.
Building just outside a First Schedule limit. A 60 sqm storage platform or a 1.8 m retaining wall is no longer exempt.
Starting first and looking for a PE later. Carrying out building works without approved plans or a permit carries a fine of up to $200,000, imprisonment of up to 2 years, or both under the Building Control Act. Our article on regularisation and recent enforcement covers what follows.
A simple three-question test
Ask these three questions in order.
Does the work touch structure, or exceed a First Schedule limit? If it alters a beam, column, slab, load bearing wall or foundation, or exceeds a limit in List 2, treat it as building work that needs a Qualified Person and BCA approval.
Does another rule name a PE or Authorised Examiner? Check List 1: scaffolds, tower cranes, excavations over 1.5 m, temporary buildings, signboards, lifting equipment, pressure vessels, PSI and PFI.
Does the owner of the premises, the main contractor or the insurer require one? Check the HDB guidelines, the management corporation's renovation rules, the landlord's fit-out manual and the contract.
If all three answers are a confident no, a PE endorsement is unlikely to be required. If you cannot answer the first question with confidence, that is the point to ask an engineer.
FAQ
When is PE endorsement required for wall hacking?
It is required by law when the wall is structural, because that is building work needing BCA approval and a permit. For a non-load bearing wall, BCA approval is not needed, but HDB approval is, and condominium managements commonly require a PE's certification.
Is PE endorsement required for HDB renovation?
HDB requires a PE for civil or structural works to supervise demolition of non-structural reinforced concrete elements. Ordinary partition wall removal needs HDB's approval but HDB's guideline does not name a PE for it.
Is PE endorsement required for scaffolding?
Only for the cases MOM lists, such as metal scaffolds exceeding 30 m in height outside shipyards, scaffolds on cantilever or jib supports, and loads or numbers of persons above the stated limits.
Do I need a PE for a signboard?
A PE applies for a Permit to Use when the sign exceeds 10 sqm on an advertising structure, or the structure exceeds 10 sqm or reaches 4 m or more above the surface it stands on.
Is there a PE endorsement form?
There is no single form. Each regime has its own certificate, such as BCA's standard certifications for structural plans. See PE endorsement form and documents.