URA Envelope Control for Landed Houses: Storeys Setbacks Attics and Basements

Nov 12
8 min read

URA's envelope control guidelines, applied to all landed housing since 11 May 2015, define the three-dimensional box a landed house must fit inside, based on the storey control for the area and the building setbacks. In a 2-storey area the overall height is capped at 12.0 m (8.5 m to the top of the second storey plus a 3.5 m attic zone); in a 3-storey area it is 15.5 m (12 m plus 3.5 m), with the attic contained within a 45-degree line. A house's permissible gross floor area is whatever fits inside that envelope after setbacks and, for bungalows, site coverage.

The figures below are taken from URA's Development Control handbooks for bungalows, semi-detached and terrace houses, with each page's last-updated date. They are general guidelines; URA states it may depart from them where a case warrants, so your QP should confirm against the live pages and any street block plan. This article is part of our landed house rebuild guide.

How many storeys can a landed house have?

A landed house may not exceed the 2-storey or 3-storey height control, or the storey height shown for the area in the Designated Landed Housing Area Plan in the Master Plan, whichever is lower (URA envelope control page, last updated 7 June 2026). Landed houses outside Designated Landed Housing Areas and not guided by street block plans are subject to a 3-storey height control (URA locational criteria, last updated 6 November 2026). Absolute technical height limits, such as aviation paths, and conservation or urban design height controls take precedence if stricter. Check your plot on URA SPACE before any design starts.

What are the height limits under envelope control?

URA's envelope control diagrams set these maximums:

  • 2-storey area: 8.5 m from the external platform level to the top of the second storey, plus a 3.5 m attic zone, for an overall height of 12.0 m.

  • 3-storey area: 12 m to the top of the third storey, plus a 3.5 m attic zone, for an overall height of 15.5 m.

  • The attic zone is bounded by a line at a maximum of 45 degrees from the top of the main walls.

  • A lift overrun and safety barriers on an RC flat roof may go up to 1 m beyond the allowable height.

Height is measured from the external platform level. Where the site already has two distinct platform levels, the envelope can be taken separately from each. On sloping sites, the envelope is taken from the allowable platform levels at the front and rear setback lines and connected diagonally, and protrusions of up to 1 m are allowed for spaces that transition between levels. In low-lying areas, overall height is measured from PUB's Minimum Platform Level (MPL).

Can I build a mezzanine or an attic?

Yes, both are allowed if they stay inside the envelope. URA no longer requires mezzanines to be kept below 50% of a typical floor plate, but a house with a mezzanine must still fit the 12 m or 15.5 m overall height. URA's lodgment criteria allow no more than one full mezzanine floor within the permissible envelope.

An attic is "an incidental space" allowed within the envelope, and URA's diagram notes no height restriction for the attic floor itself as long as the form stays inside the 3.5 m, 45-degree zone. Roof terraces on attic roofs must be at least 3 m below the top of the permissible envelope, so that any covering a homeowner adds later still fits. Roofs less than 3 m below the top must be RC flat roofs that are not accessible except for maintenance. Dormer windows may protrude up to 1 m vertically and horizontally beyond the envelope (URA circular, 1 March 2025).

Can a landed house have a roof terrace?

RC flat roofs must remain inaccessible except for maintenance, though URA may allow a roof terrace on the merits of the proposal, with any structures and safety barriers within height controls (URA RC flat roofs page, last updated 20 July 2026). Safety barriers for maintenance access must not exceed 1 m in height. The car porch roof may be used as an open-to-sky balcony or garden with a parapet of up to 1 m in visually porous material; the car porch itself must not exceed 4.5 m in height (URA building appendages, last updated 7 June 2026).

What setbacks apply to a landed house?

Setbacks depend on the road category in front and on whether the plot is in a Good Class Bungalow Area. URA's tables (setback pages, last updated 6 November 2026):

  • Road buffer for the main building: 24 m on Category 1 roads and 12 m on Category 2 roads (each including a 5 m green buffer), and 7.5 m on Category 3, 4, slip and Category 5 roads (including a 3 m green buffer except on Category 5).

  • Car porch on Category 3 to 5 roads: 2.4 m from the road, applying to a car porch up to 3 m wide column to column.

  • Terrace or patio on Category 3 to 5 roads: 2.4 m outside GCBA; 5.1 m within GCBA.

  • Common boundaries (side and rear): 2 m for the main building, car porch columns and terraces outside GCBA; 3 m within or abutting a GCBA.

  • Roof eaves: 1 m from common boundaries outside GCBA; 1.6 m within or abutting a GCBA.

  • Terrace Type II houses: a standard 2 m setback from the road for the building wall and 1 m for roof eaves.

Minor appendages may protrude into setbacks by fixed amounts, for example main roof eaves up to 2 m into the road buffer and 1 m into a common boundary setback outside GCBA, while bay windows may not encroach into either. For existing irregular plots on Category 4 or 5 roads, the 7.5 m road setback applies for 8 m from the neighbour's boundary, beyond which a 2 m setback may be allowed. Rear extensions of terrace and semi-detached houses may abut existing back lanes 4 m to 6 m wide, limited to the first-storey height.

What about corner plots?

Corner plots have both a larger minimum size and additional road frontage to respect. A corner terrace (Type I) needs a minimum plot of 200 sqm and width of 8 m, against 150 sqm and 6 m for an intermediate unit (URA terrace plot size page, last updated 7 June 2026). For an individual bungalow plot with more than one road frontage, URA publishes separate setback diagrams for Category 5 and other roads, and for developments of several houses the road buffer applies along the development boundary even where it fronts two Category 5 roads. A terrace house can be redeveloped into a bungalow only if the neighbour left behind can still qualify as a corner terrace of at least 200 sqm and 8 m wide.

What are the minimum plot sizes, widths and site coverage?

Plot size and width are measured net of land to be vested in the State, such as road and drainage reserves (URA plot size pages, last updated 7 June 2026):

  • Good Class Bungalow: 1,400 sqm, 18.5 m wide, 30 m deep.

  • Bungalow outside GCBA: 400 sqm, 10 m wide.

  • Semi-detached: 200 sqm; 8 m wide side-to-side, 10 m back-to-back.

  • Terrace Type I: intermediate 150 sqm and 6 m; corner 200 sqm and 8 m.

  • Terrace Type II: intermediate 80 sqm and 6 m; corner 80 sqm and 8 m.

Site coverage applies to bungalows only; there is no site coverage control for terrace houses. Bungalows have a two-tier control: overall site coverage, counting all building features raised 1 m or more above ground, of 50% outside GCBA and 45% within GCBA; and a sub-control up to the external facade, including balconies, planters, bay windows, roof terraces and half the car porch roof, of 40% outside GCBA and 35% within (URA site coverage page, last updated 7 June 2026). Sun-shading features are excluded from the sub-control.

What counts as a basement?

URA allows basements up to set limits and treats spaces below PUB's Minimum Platform Level in low-lying areas as a basement rather than an extra storey. URA's basement rules (envelope control page):

  • A basement with protrusion above ground may extend up to the road buffer and up to the building setback from other boundaries.

  • A fully submerged basement may extend to the road reserve line if the part under the green buffer is at least 2 m below ground, and outside GCBA up to the lot boundary, provided there are no technical requirements such as sewerage or drainage and no adverse impact on the adjoining property; walls on the boundary may have no openings.

  • Within GCBA, fully submerged basements must be set back 2 m from the boundaries.

  • In low-lying areas, spaces below the MPL must be fully sealed with no external openings; if openings are proposed, PUB requires the internal floor to be at least 300 mm above the adjacent road and bedrooms and M&E installations to be above the MPL.

On sloping sites, an exposed basement protrusion may be considered if it stays within the envelope height. See basements in landed houses.

What must the engineer design around?

The envelope is a planning box, but almost every limit becomes a structural or geotechnical problem:

  • A basement built to the lot boundary means an earth retaining wall right against the neighbour's foundations, with no openings and no adverse impact allowed. Excavation over 1.5 m needs BCA plan approval, over 4 m an Accredited Checker, and over 6 m it is geotechnical building works (BCA ERSS requirements, June 2026). See ERSS thresholds.

  • Fixed overall heights with mezzanines and attics squeeze floor-to-floor heights, so the engineer must keep beam depths and structural zones tight while still carrying the spans the layout needs.

  • Setback rules for appendages limit cantilevers and transfer structures at the edges of the envelope.

  • Earthworks within setbacks are generally not allowed and capped at 1 m where permitted; retaining walls facing the street are capped at 1 m, boundary walls at 1.8 m and combined walls at 2.8 m (URA earthworks and retaining walls pages, last updated 7 June 2026). See retaining walls and slopes for landed houses.

  • Raising the platform to the MPL changes the foundation levels, drainage and the height of every boundary wall.

FAQ

What is envelope control for landed houses?

It is URA's rule, in force since 11 May 2015, that limits a landed house to a building envelope defined by storey height and setbacks, instead of a fixed floor area.

What is the maximum height of a 2-storey landed house?

12.0 m overall: 8.5 m for two storeys plus a 3.5 m attic zone, measured from the external platform level.

What is the maximum height of a 3-storey landed house?

15.5 m overall: 12 m for three storeys plus a 3.5 m attic zone.

Does an attic count as a storey?

An attic within the 3.5 m, 45-degree attic zone is treated as an incidental space within the envelope. A roof terrace on it must be at least 3 m below the top of the envelope.

Can a landed house basement go up to the boundary?

Outside GCBA, a fully submerged basement may extend to the lot boundary if there are no technical constraints, no adverse impact on the neighbour and no openings on the boundary wall. Within GCBA it must be set back 2 m.

Do terrace houses have a site coverage limit?

No. URA states there is no site coverage control for Terrace Type I or Type II houses; bungalows have a 50% (45% in GCBA) limit.